 BXF400 Series
DC/DC CONVERTERS
* * * * * * * * * * *
Single output
264W Wide Input DC/DC Converters 1
Industry standard footprint Adjustable output voltage with output currents of 80A No minimum load required 2:1 input range for battery powered applications Undervoltage lockout (UVLO) Overvoltage and overcurrent protection Synchronisable and parallelable with load sharing Overtemperature and short circuit protection Current monitor and power good signal Remote ON/OFF Available RoHS compliant
BXF400 Series high power density DC/DC converters can provide up to 80A output current and have an industry-standard footprint, measuring just 2.40 x 4.60 x 0.52 inches. These converters have the highest output current rating of any comparably-sized products on the market, are equally suitable for new designs or as replacement power sources in existing equipment. BXF400 Series converters are designed specifically for redundant and distributed power systems in the computer and telecommunications sectors, but their feature-rich specifications make them suitable for a very wide range of applications. Using Bellcore 332, the MTBF is over 1,000,000 hours. Aluminium baseplate technology and four threaded M3 inserts make heatsink attachment and thermal management easy. The BXF400 Series is approved by UL, CSA and VDE.
All specifications are typical at nominal input, full load at 25C unless otherwise stated
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS Voltage adjustability Set point accuracy Line regulation Load regulation Minimum load Overshoot Undershoot Ripple and noise Temperature coefficient Transient response Remote sense INPUT SPECIFICATIONS Input voltage range Input current Input current (max.) Input reflected ripple 48Vin nominal No load Remote OFF (See Note 3) (See Note 5) 36 to 75VDC 100mA max. 20mA max. 12A max. 35mA pk-pk Recovery time (See Note 2) Peak deviation At turn-on and turn-off 5Hz to 20MHz (See Note 1) Model specific 0.5% typ., 1.6% max. Low line to high line Full load to min. load 0.10% typ. 0.15% typ. 0% 0V 0V 20mV 0.01%/C 500s 500mV
EMC CHARACTERISTICS Conducted emissions (See Note 7) Bellcore 332 FCC part 15 EN55022, CISPR22 Level A Level A Level A
GENERAL SPECIFICATIONS Efficiency Isolation voltage Input/case Input/output Output/case Fixed See table 1500VDC 1500VDC 1500VDC 850kHz typ. VDE0805, EN60950, IEC950 UL1950, CSA C22.2 No. 950 Aluminium baseplate and plastic casing UL94V-0 200g (7.06oz) Bellcore 332 MIL-HDBK-217F @ 40C, 100% FL >1,000,000 hours >200,000 hours
Switching frequency Approvals and standards (See Note 4) Case material Material flammability Weight MTBF
0.5VDC transmission line drop compensation
ENVIRONMENTAL SPECIFICATIONS Thermal performance Altitude Operating case temp. -40C to +100C -55C to +125C Non-operating Operating Non-operating 5Hz to 500Hz 10,000 feet max. 40,000 feet max. 2.4G rms (approx.)
Active low remote ON/OFF Logic compatibility ON OFF Undervoltage lockout Start-up time (See Note 6) 48Vin: power up 48Vin: power down Power up Remote ON/OFF
1.2VDC max. Open circuit 34.8V 33.1V 15ms 13ms
Vibration
File Name: BXF400.pdf Rev: 30 Mar 2006
BXF400 Series
DC/DC CONVERTERS
OUTPUT POWER (MAX.) 264W Notes
1 2 3 4 5 6 7 8
Single output
264W Wide Input DC/DC Converters 2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
INPUT VOLTAGE 48VDC OUTPUT VOLTAGE 3.3V INPUT OUTPUT CURRENT CURRENT (MAX. LOAD) (MAX.) 7.0A 80A EFFICIENCY (TYP.) 78% REGULATION LINE 0.10% LOAD 0.15% MODEL NUMBER (8) BXF400-48S3V3LJ
OVP 3.8 VDC
PROTECTION Short circuit protection Overvoltage protection Undervoltage protection Thermal protection TELECOM SPECIFICATION Central office interface A ETS300-132-2 Continuous, automatic recovery Latching Non-latching 110C baseplate, automatic recovery
Measured with 10F tantalum capacitor and 1F ceramic capacitor across the output. Iout = Inom; delta Iout = 25% Iout (max), di/dt = 1A/s. Input fusing is required based on surge and maximum input current. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. Input reflected ripple current test set-up uses a Pi filter; 220F, 12H, 100F. Start-up into resistive load. Units should be characterised within systems. External components and filtering required. The `J' suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details..
PIN CONNECTIONS PIN NUMBER 1 2 3 4 5 6 FEATURE Power Good Current Monitor Parallel Trim Adjust + Sense - Sense
EXTERNAL OUTPUT TRIMMING Output can be externally trimmed by using the method shown.
8
TRIM UP
7
TRIM DOWN
6
RT1 OR RT2
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. 10401-3336-0148 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C
File Name: BXF400.pdf Rev: 30 Mar 2006
BXF400 Series
DC/DC CONVERTERS
Single output
264W Wide Input DC/DC Converters 3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
TOP VIEW WITH OVERALL DIMENSIONS
2.40 2.00 (61.0) (50.8)
THREADED INSERTS M3 x 0.5 THROUGH 4 PLACES
4.20 (106.7) 4.60 (116.8)
SIDE VIEW 0.53 (13.5) 0.00 (0.0) 0.20 (5.1) MIN. 2.600 (66.04) All dimensions in INCHES (mm). Tolerance: x.xx 0.02in. (0.51mm). x.xxx 0.010in. (0.254mm).
0.040 0.002 (1.02 0.05) DIA. 3 PLACES
BOTTOM VIEW PIN DETAILS
0.062 0.002 (1.57 0.05) DIA. 11 PLACES
246 CASE S2 S1 PRI ENABLE VINVIN+ 0.040 0.002 (1.02 0.05) DIA. 6 PLACES BOTTOM VIEW DIMENSIONAL DETAILS 1.70 (43.2) 1.50 (38.1) 1.20 (30.48) 0.900 (22.86) 0.700 (17.78) 0.500 (12.70) 0.300 (7.62) 0.000 (0.00) 0.500 (12.70) 0.70 (17.8) 0.000 (0.00) 0.20 (5.1) 2.600 (66.04) 4.20 (106.7) 4.40 (111.8) 0.100 (2.54) 246 135 0.100 (2.54) 5 PLACES 0.200 (5.08) 7 PLACES 0.000 (0.00) 0.50 (12.7) 1.50 (38.1) 1 35 VOUTVOUTVOUTVOUTVOUT+ VOUT+ VOUT+ VOUT+
All dimensions in INCHES (mm). Tolerance: x.xx 0.02in. (0.51mm). x.xxx 0.010in. (0.254mm).
Datasheet (c) Artesyn Technologies(R) 2006 The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: Application Note
www.artesyn.com
File Name: BXF400.pdf Rev: 30 Mar 2006


▲Up To Search▲   

 
Price & Availability of BXF400

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X